logo GAS DETECTION SYSTEMS FOR SAFE ENERGY
  

  Home

  Contact Neodym

  Part Number Generators
    - Knowz™
    • KnowzNet™ Panel
    - KnowzNet™ Sensors
    - MiniKnowz™
    - ProtiSen™
    - HydroKnowz™
    - Panterra
    - PowerKnowz™

  Products

  Order Online

  Privacy Policy

  Site Map

  Technical Support

  Terms of Use

 
  K n o w z N e t™

KnowzNet
  K n o w z N e t™

8-sensor any gas detection system with
master relay & optional zone relays.

Price range: $713 to $941 (Panel only)

Heads: $82 to $283 depending on type

Add panel(s) and head(s) to cart via respective part number generators.
 
Product Links

> Features
> Details
> Specifications
> Datasheet (PDF)
> Ordering options
> PANEL Part No. Gen.
> HEADS Part No. Gen.
> Gallery


  PART NUMBER GENERATOR

The most commonly selected options have been checked as defaults. If your preferred configuration is not selectable below, then please contact Neodym.

Default Target Gas and Alarm Level(s)

Please note: This selection relates to the default sensor port drivers that will be installed at order time. Each sensor port is user-configurable via the NeoPort™ set-up program.

 TARGET GASALARM
Hydrogen (0-80% LEL) %LEL
Methane (0-80% LEL) %LEL
Propane (0-80% LEL) %LEL
Refrigerant (0-5K ppm) ppm
Oxygen (0-30% vol.) - %
Carbon monoxide (0-450 ppm) - Requires PowerKnowz head ppm


Zone Relays

A master (all zone) relay is standard. Check button below if individual zone relays are required.

   Zone relays required.


Input Power Supply

   12 - 16 VDC     14 - 40 VDC     14 - 60 VDC


Back-up Battery

(Only available for 12 - 14 VDC systems)

   none     2 hours     4 hours     8 hours

Note: Panels with battery back-up option require 15 VDC input power


Sensor Port Connectors

  3.5mm 4-conductor terminal blocks
  Hirose DF3 2mm 4-pin headers



AC Power Supply

  None
  110 VAC-to 12 VDC 1A (4 sensors)
  110 VAC-to 12 VDC 2A (8 sensors)
  110 VAC-to 15 VDC 1.6A (Battery back-up systems)










KNOWZNET™ PART NUMBER FIELDS

  KN Gxx Axxx/yyy Zn In Bn Kn Pn  
Field: -1- --2-- ------3------ -4- -5- -6- -7- -8-  

1: KnowzNet™ product family identifier.

2: Target gas. xx = sensor code.

3: Alarm level. xxx = high alarm, yyy = low alarm.

4: Zone relays. 0 = none. 1 = installed.

5: Input power supply. 1 = 12VDC. 2 = 14-40VDC. 3 = 14-60VDC

6: Back-up battery. 0 = none. 2 = 2 hrs. 4 = 4 hrs. 8 = 8 hrs.

7: Port connectors. 2 = 3.5mm terminal blocks. 3 = 2mm Hirose headers.

8: AC adapter(s). 1 = 12VDC 1A. 2 = 12VDC 2A. 3 = 15VDC 1.6A


©1999-2022 Neodym Systems Inc. All rights reserved.