logo GAS DETECTION SYSTEMS FOR SAFE ENERGY
  

  Home

  Contact Neodym

  Part Number Generators

  Products
    - Accessories
    - Evaluation Kits
    - Comparative Matrix
    - HydroKnowz™
    - ProtiSen™
    - Panterra
    - PowerKnowz™
      - Features
      - Details
      - Specs.
      • Options
      - Gallery
      - Features
      - Details
      - Specs.
      - Options
      - Gallery
    - MiniKnowz™
    - Knowz™
    - KnowzNet™
    - Under Development

  Order Online

  Privacy Policy

  Site Map

  Technical Support

  Terms of Use

 
  P o w e r K n o w z ™

PowerKnowz
  P o w e r K n o w z ™

Combustible gas / CO detector with optional relay.



   $68 to $147 - Combustibles (0-50% LEL)

 $136 to $215 - Carbon monoxide (0-450 ppm)

 (Add to cart via part number generator)
 
Product Links

> Features
> Details
> Specifications
> Datasheet (PDF)
> Ordering options
> Part No. Generator
> Gallery

Related Links

> Eval. Kits
> PK-Port™ (PDF)
> Product Matrix


  PRODUCT ORDERING OPTIONS

Our on-line question-and-answer part number generator simplifies the selection of product options. A link to the part number generator is in the Product Links section above.

Action Level Options

Alarm level specified as "PK-Gx-Annn", where:
  "x" is the target gas: H / M / P / C
  "nnn" is alarm conc./resolution
  EG: Hydrogen 10,000 PPM is "PK-GH-A100"
  Note: 10-75% of sensor range only.
Warning level specified as "Wpp", where:
  "pp" is percentage code.
  Percentage code is 20-80% of alarm level


Calibration Options

Devices can be ordered with & without the offset button & span trimpot. We recommend fixed calibration for high vibration and tamperproof applications. Field access to calibration values is securely available via PK-Port.


Error Handling Options

1. Audio-visual indication of errors [E1]
2. Errors trigger alarms (fail safe) [E2]


Overdose Handling Options

1. Failure to hypersensitivity [X1]
2. Failure to persistent error state [X2]


Output Signal Option

1. TTL - Norm.-high, Auto (self-clearing) [O1]
2. TTL - Norm.-low, Auto (self-clearing) [O2]
3. TTL - Norm.-high, Latch (Button reset) [O3]
4. TTL - Norm.-low, Latch (Button reset) [O4]

   (Specify TTL signal to respond to warning    state, alarm state, or both.)

5. Proportional output - 0 to 5VDC [O5]
    0.5V safety offset (zero reading)
    200 steps of 20mV each
    Each step equals one resolution unit
  Relay Options

1. Relay not required [R0]
2. Normally-closed, Auto (self-clearing) [R1]
3. Normally-open, Auto (self-clearing) [R2]
4. Normally-closed, Latch (Button reset) [R3]
5. Normally-open, Latch (Button reset) [R4]

Specify relay to respond to warning state, alarm state, or both.


Audio Sounder Options

1. No beeper [S0]
2. Includer beeper [S1]


Enclosure Options

1. Open-frame (Circuit board only) [P0]
2. Anodized aluminum case (No flange) [P1]
3. Anodized aluminum case (With flange) [P2]


Powering Options

1. 5 VDC (+/- 5%) [I1]
2. 7-to-40 VDC switch mode PSU [I2]
3. 7-to-60 VDC switch mode PSU [I3]


Interface Connector

1. Molex 6-pin Mini-Fit Jr. header

  - Pin 1: Input power (+)
  - Pin 2: Ground (common)
  - Pin 3: Output signal
  - Pin 4: Dry relay contact #1
  - Pin 5: Dry relay contact #2
  - Pin 6: PK-Port interface

Custom connectors & harnesses are available with nominal NRE. Please call or email to discuss custom requirements.


©1999-2022 Neodym Systems Inc. All rights reserved.